Command Reference Guide
Chapter 1: Matrix Server Commands 26
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
processing. Numbers are the raw counter values, not computed per sample.
The syntax for the command is:
rawstat [interval [count]]
interval is the number of seconds between samplings. The default is one
second. count is the number of samples to make; the default is to sample
indefinitely.
The output consists of ASCII text delimited by carets. The fields are:
1. PSD device name
2. Sample number
3. Sampling interval
4. Number of targets
5. Current active target
6. Number of I/O sizes
7. First I/O size (power of 2)
8. Number of I/Os queued (includes raw)
9. Number of raw I/Os queued
10. Number of MP failovers
11. Number of MP fatal errors
12... Per-target I/O statistics in tuples, or groups of two numbers. (The
number of targets is indicated in field 4.) Each tuple consists of the
following fields for each target:
• SCSI I/Os queued
• Transient failures
Note that the “SCSI I/Os queued” numbers are for the underlying disk,
not the partition. PSD devices that share the same underlying disk will
share the same numbers here.