Command Reference Guide

Chapter 1: Matrix Server Commands 15
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
--version
Display the version of Matrix Server.
-m, --monitor
Explicitly tell mxinit to monitor processes. This is the default when mxinit
is invoked to start Matrix Server.
-M, --no-monitor
Explicitly tell mxinit not to monitor processes.
--hba-status
Display the state of the FibreChannel host bus adapter drivers.
--status
Display the status of Matrix Server processes and modules. Following is
an example.
$ status
PolyServe Matrix Server Status:
Name pid / status
mxinit 15930 mxinit: Monitoring MxS processes
mxlog Loaded
grpcommd 15885
mxlogd 15887
pswebsvr 15890
clusterpulse 15892
panpulse 15912
psd_devfs Loaded
psfs Loaded
dlm 15913
sanpulse 15917
FibreChannel adapter module status:
qla2300 - QLogic 2300 FibreChannel Adapter, is Loaded
The PID is displayed for running processes; “Stopped” is displayed for
processes that are not running. For modules, the status specifies whether the
module is loaded. The “FibreChannel adapter module status” section
displays status for the FibreChannel adapter modules installed on the system.