1. Transceiv
er 01
2. Transceiver 02
3. Transceiver 03
4. Transcei
ver 04
Figure 37 Transceiver element numbers
Table 27 Tra
nsceiver error conditions
Error
condition
code
Severity Description Actions
0.F.en.01
Critical Transceiver en is incompatible with the
I/O module.
0.F.en.02
Critical Transceiver en can not detect a data
signal.
0.F.en.03
Critical
Fibre Cha
nnel DS2500 bus fault involving
transcei
ver en
Contact your HP-authorized
service representative.
0.F.en.04
Critical The EMU detects that transceiver en has
been removed.
Install a new transceiver.
0.F.en.05
Critical An invalid Fibre Channel character was
detected in the incoming data stream on
transceiver en.
Contact your HP-authorized
service representative.
Voltage sensor and current sensor error conditions
The format of a sensor error condition reports is 1.2.en.ec for a voltage sensor, and 1.3.en.ec for a
current sensor, where:
• 1.2. identifies a voltage sensor error.
• 1.3.identifies a current sensor error.
• en. identifies the location of the affected sensor (see Table 28).
When viewed from the rear of the enclosure, power supply 1 is on the left, and power supply 2
is on the right.
• ec is the error code.