User's Manual

Table 23 Blower error conditions
Error
condition
Severity Description Actions
0.3.en.03
Unrecoverable Blower en has st
opped.
0.3.en.04
Unrecoverable Power supply en has detected an
internal blower error.
0.3.en.05
Noncritical Blower en is missing or is improperly
installed.
Replace the blo
wer as soon as
possible.
0.3.en.06
Unrecoverable No blowers are installed.
Enclosure shutdown is imminent.
When this condition exists there will be
two error messages:
0.3.en.05 identifies the first blower
0.3.en.06 identifies the second
blower
The EMU will shut down the
enclosure in 7minutesunless
you install blowers.
Temperature error conditions
The format of a temperature sensor condition report is 0.4.en.ec,where:
0.4. identifies a temperature sensor error.
en. ident
ifies the location of the affected temperature sensor.
ec provides details about the error.
See Table 24 to determine the location of each temperature sensor.
Table 24 T
emperature sensor element numbers
Element number
(en.)
Sensor location Element number
(en.)
Sensor location
01.
Power supply 1
10.
Drive bay 7
02.
Power supply 2
11.
Drive bay 8
03.
EMU
12.
Drive bay 9
04.
Drive bay 1
13.
Drive bay 10
05.
Drive bay 2
14.
Drive bay 11
06.
Drive b
ay 3
15.
Drive b
ay 12
07.
Drive bay 4
16.
Drive bay 13
08.
Drive bay 5
17.
Drive bay 14
09.
Drive bay 6
80
EMU-generated error condition reports