User's Manual

CXO7373A
2
3
1
1. EMU alphanumeric display
2. Function
select
3. Display group select
Figure 21 EMU alphanumeric display and controls
c. Verify the state of the following status indicators (Figure 22).
Both power supply status indicators are on.
The EMU heartbeat is flashing.
The EMU enclosure power LED is on.
Both I/O module power status indicators are on.
All four I/O module port status indicators are off.
25204a
Figure 22 Enclosure operational status indicators
Connec
ting the cables
Figure
23 shows a FC-AL configuration with the maximum allowed DS2500s.
To con
nect fibre optic cables on a direct connect model:
1. Remove the dust covers from the I/O module ports.
2. Insert an SFP in each I/O port.
3. Attac
h one end of an FC cable to I/O module A—port 2 SFP, and the other end of the cable to
either:
The SFP in port 1 of I/O module A on the preceding enclosure if you are adding the DS2500 to
an ex
isting storage system, or
The HBA if the DS2500 is the first or only enclosure.
2500 Disk System user guide
33