User guide
Configuring the switch116
CAUTION: Use extreme care when configuring PDCMs for E_Ports, as mistakes can render paths
unusable and cause complex routing problems. These problems can be difficult to detect and
sometimes manifest as end-device issues.
Figure 40 Configure Addresses - “Active” dialog box
3. Click Save As to open the Save Address Configuration As dialog box.
4. Click the Port Name box and enter a name.
Names must be between 1 and 8 characters in length. Valid characters are uppercase A–Z,
0–9, hyphen (-), and underscore (_). The name may not be CON, AUX, COMn (n=1–49), LPTn
(n=1–39), NUL, or PRN.
5. Optionally click CUP Name and enter a CUP name.
A CUP name must be between 1 and 24 characters. All characters in the ISO Latin - 1 character
set are allowed, except for control characters. The space character is not allowed as the first
character, and characters are case sensitive.
6. Click OK to save changes and to close the Save Address Configuration As dialog box.
7. In the Configure Addresses - “Active” dialog box, click Activate to activate the configuration or
click Cancel to close without activating.
NOTE: If you click Cancel after saving, your configuration will still be added to the library
without being activated.