Manual

Monitoring and managing the director76
The Node Properties dialog box contains the following options:
Port NumberThe physical port number on the director to which the node is connected.
Fibre Channel Address—In Open Systems style only, this displays the three-byte Fibre Channel
Address of the node.
Port Address—In FICON Management Style only, this displays the logical address (hexadecimal
number) for the port where the node is attached.
Port WWN—Port World Wide Name of the attached device.
Port NicknameNickname for the port WWN. Must be configured to display.
Node WWN—Node World Wide Name of the attached device. Must be configured to display.
Node Nickname—Nickname for the node WWN.
Unit Type—See the “Unit Type” bullet on page 73 for a description.
Buffer-to-Buffer Credit—The buffer-to-buffer credit that the attached node has available.
Class of Service—Class of service. This can be Class 2, Class 3, or both.
Data Field Size—Data field size. This is the largest size of Fibre Channel frame the node will
process. The size is negotiated with the attached device.
TypeType number.
Model—Model number.
Sequence #—Sequence number.
Tag—tag number.