Manual

Director Element Manager user guide 31
Open Systems Management Style—For each port you can provide a name, block or
unblock operation, configure extended distance buffering for 10 to 100 km, enable LIN
alerts for each port, define a type (G, F, or E), set the speed, enable Port Binding, and enter
a WWN or nickname.
NOTE: Ports are automatically configured as G_Ports if no device is connected, F_Ports if a
device is connected, and E_Ports if a director is connected.
In both styles, you can enable the rerouting delay feature, and for the Director 2/64 only, you
can set the director data speed.
NOTE: Note that your director model and firmware may not allow variable data speeds.
Allow/Prohibit Matrix (FICON Management only)—Select one of the following
options:
Active Addresses—Displays the Configure-Addresses—“Activedialog box. Use this dialog
box to configure a name, blocked or unblocked state, and prohibited and allowed
connection attributes for a port.
Stored Addresses—Displays the Address Configuration Library. Use this dialog box to
activate, modify, delete, and modify existing address configurations created through the
Active Addresses dialog box.
SNMP Agent—Displays the Configure SNMP dialog box. Use this dialog box to:
Configure network addresses and community names for up to six SNMP trap recipients.
Authorize write permissions to enable SNMP management stations to modify writable MIB
variables.
Enable authorization traps to be sent to management stations when unauthorized stations
request access to director SNMP data.
FICON Management Server—Displays if the FICON Management Server in-band
management feature was enabled through the Configure Feature Key dialog box. (See
Configuring the feature key” on page 136 for more information.) You can select the following
suboptions:
Enable FMS—Displays a check mark and enables the FICON Management Server.
Parameters—Displays the Configure FICON Management Server dialog box. Use this
dialog box to perform the following tasks:
Allow or prohibit director clock alert mode.
Allow or prohibit programmed off line state control.
Select a code page from the Code Page list.
For details, seeFICON Management Server” on page 183.
Open Systems Management Server—Displays if the Open Systems Management Server
in-band management feature was enabled through the Configure Feature Key dialog box. (See