Manual

Director Element Manager user guide 181
Exit data through port 45
Make Switch 3 the destination device
To accomplish the example tasks:
1. Select Configure > Preferred Path in Switch 1’s Element Manager window to configure the path
on Switch 1.
The Add Preferred Path dialog box is displayed.
2. Click 14 in the Source Port field.
3. Click 45 in the Exit Port field.
4. Click 3 (Switch 3’s domain ID) in the Destination Domain ID field.
This procedure specifies only that data will enter and exit Switch 1 through specific ports on its way
to Switch 3. This process does not specify a preferred path for data moving through Switch 2. To
specify paths through Switch 2 (Figure 86 on page 182), we will do the following:
Enter data through port 11
Exit data through port 21
Make Switch 3 the destination device
To accomplish the previously listed tasks:
1. Select Configure > Preferred Path in Switch 2’s Element Manager window to configure the path
on Switch 2.
The Add Preferred Path dialog box is displayed.
2. Click 11 in the Source Port field.
3. Click 21 in the Exit Port field.
Enter 3 (Switch 3’s domain ID) in the Destination Domain ID field.