Manual
Using logs156
The following acronyms may appear to describe the FRU:
• GLSL—G_Port, long wave, single mode LC connector, 1 Gigabit
• GSML—G_Port, short wave, multimode, LC connector, 1 Gigabit
• GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
• FPM—G_Port, small form factor pluggable (SFP) optics, FICON port module, 1 Gigabit
• UPM—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 Gigabit
• GSF2—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 Gigabit
• GLSR—G_Port, short wave, single mode, MT-RJ connector, 1 Gigabit
• GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit
• GSMR—G_Port, short wave, multimode, MT-RJ connector, 1 Gigabit
• Position—Slot position in the chassis relative to identical components installed
• Action—Inserted or removed
• Part Number—Part number of the component
• Serial Number—Serial number of the component
Link Incident Log
The Link Incident Log displays most recent 1,000 link incidents, the date each incident occurred, the
time it occurred, and the port where it took place. To open the Link Incident log, select Logs >
Incident Log.
Figure 71 Link Incident Log
CTP Control processor
SBAR SBAR card
BKPLNE Backplane
Table 7 FRU names (continued)