Manual

Using logs154
Each log entry includes the following:
Date/Time—The date and time of the event on the director
Event—Events are identified by a unique code. Table 6 lists the event codes and their
corresponding event types.
The Event column may also display the following acronyms to describe the port card:
GLSL—G_Port, long wave, single-mode LC connector, 1 Gigabit
GSML—G_Port, short wave, multi-mode, LC connector, 1 Gigabit
GXXL—G_Port, mixed mode, LC connector, 1 Gigabit
FPM—G_Port, small form factor pluggable (SFP) optics, FICON port module, 1 Gigabit
UPM—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 Gigabit
GSF2—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 Gigabit
GLSR—G_Port, short wave, single-mode, MT-RJ connector, 1 Gigabit
GXXR—G_Port, mixed mode, MT-RJ connector, 1 Gigabit
GSMR—G_Port, short wave, multi-mode, MT-RJ connector, 1 Gigabit
The chassis (slot) position for a non-redundant FRU is 0. The chassis positions for redundant FRUs
are 0, 1, and 2. The chassis positions for port cards are 0 through 35, and slot 32 is
unavailable.
Description—A short description of the event
Severity—One of the following classifications of severity that identify the importance of the
event:
0=Informational
2=Warning
3=Fatal
4=Fatal, not operational
Table 6 Event codes
Code Event
000–199 System events
200–299 Power supply events
300–399 Fan module events
400–499 CTP card events
500–599 Port card events
600–699 SBAR card events
800–899 Thermal events