Issues with reports when objects in the Backup Events subclass are used (IEV-27243)
The following issues occur when objects in the Backup Events subclass, located under the
Backup class, are used:
Numbers are displayed for severity levels instead of severity names in the report
- Numbers are displayed in the Severity column instead of severity names in the report.
When the Select severity filter is used, the report can only be generated when
the “All” option is used - For all other options, you are shown the following error
message and you cannot generate a report:
ORA-01722: Invalid number. Contact your Business Objects administrator
or database supplier for more information (Error: WIS 10901)
Must select certain objects to see all instances of an application, file server or an asset
with the same name (IEV-26733)
To see all instance of an application, file server or an asset with the same name, use the
objects “Application Name with Host Name,“File Server with Host Name” and “Asset Name
with ID” from their respective classes.
Not all rules are shown if certain objects are used (IEV-27082)
If a report is designed using the objects from the Rules-based Data class and its subclasses, all
the defined rules in Storage Essentials are not not displayed. Only the rules that run are
displayed. You can define rules in Storage Essentials on the Report Rules tab, which you can
access by selecting Configuration > File System Viewer in Storage Essentials.
Zone aliases are also listed under zone name objects in the Zone Configuration Details
class (IEV-27117)
Under the “Fabric” -> “Zone Configuration Details” class, zone aliases are also listed under the
zone name object when you create a report using the objects in the “Zone Configuration
Details” class.
Reports showing incorrect, incomplete, or missing data
This section describes issues with reports showing incorrect, incomplete or missing data.
“Generic HBA vendor” listing in the Prompts window has no significance in the HBA
Summary Report (IEV-26967)
A generic host bus adapter (HBA) vendor is listed in the Prompt window for the HBA
Summary report in the Report Pack. The selection of a generic HBA does not have an
influence on the output because the HBA Summary report does not show generic HBAs.
Storage-based chargeback values are incorrect when an organization with volumes exist
in the configuration (IEV-26727)
If an organization with volumes exist in the configuration, the storage-based chargeback
values will be incorrect.