User's Manual

Operations 107
Error code Error message Comment or clarification
This error can occur when you attempt to add or
drop a spare and the current configuration does not
allow a spare state change for the array.
2832
Invalid physical drive. Possible reasons for
this include: a typing error, the drive already
exists in an array, the drive type does not
match, or it is a failed drive.
A specified physical drive is not a valid physical
drive, or it cannot be placed in the array.
2833
Invalid Spare A specified spare is not a valid spare drive, or it
cannot be placed in the array as a spare.
2834
Invalid logical drive The logical drive ID is not valid.
2836
New Logical Drive ID does not match the
next available logical drive ID.
If you are attempting to replicate a
configuration that has non-consecutive
logical drive numbers, then you must
change the script file so that the logical drive
numbers are consecutive.
The script file specifies a logical drive ID that is not
the first unused ID in the sequence. For example, this
message appears if the controller has only Logical
Drive 1 and the script file specifies creation of
Logical Drive 3 (omitting Logical Drive 2). A common
cause of this error is that the input file specifies
nonsequential logical drive numbers. In this case,
change the logical drive numbers in the input file so
that they are sequential.
2837
New Logical Drive ID already exists This error occurs in Configure mode when the logical
drive ID specified in the script file already exists in
the configuration. In Configure mode, you can
create new logical drives only.
2838
Cannot create Logical Drive The array has no free space, or the maximum
number of logical drives has been reached already.
2839
Cannot migrate Logical Drive RAID The controller does not support RAID migration, or
migration is not possible with the current controller
configuration.
2841
Cannot extend Logical Drive The controller does not support extension, or the
current controller configuration cannot be extended.
For example, extension is not possible if the array
has no free space.
2842
Invalid RAID The specified RAID level is invalid or is not possible
with the current physical disk and array
configuration.
2843
Invalid Size The specified size is invalid or is not possible with the
current configuration.
2844
Invalid Stripe Size
The specified stripe size is invalid, not supported by
the current RAID level, or not possible with the
current configuration.
2849
Invalid ClearConfigurationWithDataLoss
parameter
The valid parameters are Yes and No (default).
2850
Controller does not support Chassis Name The controller does not support setting a chassis
name.
2851
Invalid Chassis Name
The entered chassis name is invalid. Use characters
from the set az, AZ, 09, !, @, #, *, (, ), ,, -, _, +,
:, ., /, and [space]. The name cannot end with a
space character or exceed the maximum number of
characters allowed by the controller.
2852
Invalid SSP State The requested SSP state is not a valid SSP state.
2853
Cannot change SSP settings The SSP settings cannot be changed for the controller