Installation Manual

Verifying the firmware update
1. After updating the firmware, cycle the power on the system and on any external JBODS
connected to the system.
2. Use saupdate LIST to confirm that the correct firmware version is installed. See “Verifying
the controller firmware (page 14).
For example:
fs0:\EFI\TOOLS> saupdate list
********************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.09.10.02
(C) Copyright 2009 Hewlett-Packard Development Company, L.P.
********************************************************************************
Seg Bus Dev Func Description Version Build
1 55 0 0 HP Smart Array P812 3.26 0
External Enclosures Connected :
Index Description Version
2 MDS600 2.62
3 MDS600 2.62
4 P812 INT EXP 3.02
1 71 0 0 HP Smart Array P411 3.26 0
External Enclosures Connected :
Index Description Version
0 MSA60 2.18
1 MSA70 2.18
2 MSA60 2.18
3 MSA70 2.18
1 C7 0 0 HP Smart Array P812 3.26 0
External Enclosures Connected :
Index Description Version
2 D2700 SAS AJ941A 0052
3 D2600 SAS AJ940A 0052
4 P812 INT EXP 3.02
1 E4 0 0 HP Smart Array P411 3.26 0
External Enclosures Connected :
Index Description Version
0 MDS600 2.62
HELP
To display usage text, program version number, and build date, enter saupdate without any
arguments.
fs1:\> saupdate
********************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.09.10.02
(C) Copyright 2009 Hewlett-Packard Development Company, L.P.
********************************************************************************
Usage: saupdate LIST
For Controller Flash:
24 Installing, verifying, and configuring the controller