Installation Manual
Table 1 <controller> strings
Meaning
<controller>
A controller having the PCI segment id, bus id, device id
and function id is addressed
<seg:bus:dev:func>
Addresses all controllers in the systemall
Controllers of a particular type indicated by the <model>
string are addressed
<model>
SET_MODE
IMPORTANT: If you are using HBA mode, do not install any disk that has previously been a part
of a RAID volume into the system.
Use set_mode to change the mode of the controller. If the controller is already in the required
mode the following message appears:
The controller at <seg:bus:dev:func> is already in HBA|RAID mode
Syntax
saupdate set_mode <controller> <hba|raid> [-f]
<controller> can be any one of the strings listed in Table 1 (page 20).
An alert message about the possible data loss is displayed when a mode change command is
issued. A confirmation is required before the actual mode change is made. This ensures that an
unintentional change of mode does not happen.
The –f indicates the user is aware of the changes that are being made, and no warning message
or confirmation regarding the mode change is needed.
20 Installing, verifying, and configuring the controller