QuickSpecs

Controller
ControllerController
Controller
mp8200 and mp8200s
mp8200 and mp8200smp8200 and mp8200s
mp8200 and mp8200s
Hard Drive Controller
1 each
Host SATA Controller
Advanced Host Controller Interface (AHCI) Revision 1.2. The specification includes a description of the
hardware/software interface between system software and the host controller hardware.
1
1
The mp8200s model ships with the SATA controller in IDE mode
Unit Environment and Operating Conditions
Unit Environment and Operating ConditionsUnit Environment and Operating Conditions
Unit Environment and Operating Conditions
General Unit Operating Guidelines
Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that unit is
operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each other's re-
circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other foreign
matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.
Temperature Range
Operating: 50° to 95° F (10° to 35° C)
*
Non-operating: -22° to 140° F(-30° to 60° C)
Relative Humidity
Operating: 10% to 90% (non-condensing at ambient)
Non-operating: 5% to 95% (non-condensing at ambient)
Maximum Altitude
(unpressurized)
Operating: 10,000 ft (3048 m)
Non-operating: 30,000 ft (9144 m)
* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Power SupplyPower Supply
Power Supply
mp8200 and mp8200s
mp8200 and mp8200smp8200 and mp8200s
mp8200 and mp8200s
Standard Efficiency
N/A
High Efficiency
Integrated graphics:
135W active PFC 87% efficient
Discrete graphics:
180W active PFC 87% efficient
Operating Voltage
Range
90 - 264 VAC
Rated Voltage Range
100 - 240 VAC
Rated Line Frequency
50/60 Hz
Operating Line
Frequency Range
47 - 63 Hz
Rated Input Current
N/A
Rated Input Current with
Energy Efficient
*
Power
Supply
135W: 2.4A
180W: 2.9A
QuickSpecs
HP SignagePlayer mp8200 Series
HP SignagePlayer mp8200 SeriesHP SignagePlayer mp8200 Series
HP SignagePlayer mp8200 Series
Technical Specifications
DA - 14115 Canada — Version 1 — September 8, 2011