Specifications

EVIS EXERA XENON LIGHT SOURCE OLYMPUS CLV-160
Primary Features for
Powerful Performance
Powerful 300W xenon lamp for Olympus
color CCD videoscope system.
New and improved condenser design helps
achieve nearly 1.3 times as much light
intensity as the CLV-U40.
Illumination capability to cover even more
distant points assures sufficient brightness
when retroflexing the scope tip, observing
the lower esophagus, and more.
Improvement in light adjustment levels
helps maintain appropriate brightness even
when observing at extremely close range or
observing the gastric angulus from directly
in front.
35% reduction in overall size compared to
its predecessor, with width reduced by a full
80 mm, saving space in your endoscopy
suite.
Simple membrane switches and clear
indicators on the front panel for improved
operability.
Compatible with conventional Olympus
color CCD videoscopes and fiberscopes.
Specifications
Automatic
brightness control
Air feeding
Water feeding
Indicators on
front panel
Setting memory
Illumination
Classification
(medical electrical
equipment)
Power supply
Size
Servo-diaphragm method
17 steps
Diaghragm pump
4-level switching by switches (OFF,L,M,H)
Air pressurization or detachable water container
Reports absence of emergency lamp, disconnection
and use of emergency lamp.
Identifies a special-purpose filter setting.
Settings (except filter setting) are stored by an internal
battery even when the power is turned OFF.
Xenon short-arc lamp (ozone-free) 300 W
Approx. 500 hours on continuous use (On intermittent
use, the lamp life may vary slightly.)
Switching regulator
Light-path diaphragm control
Forced-air cooling
Possible by using exchangeable filter
Halogen lamp 12 V 100 W
Approximately 100 hours
Class
Type BF applied part (The applied part where classification
types are not marked is Type BF applied part.)
NTSC 100–120 V AC, PAL 220–240 V AC
50/60 Hz
NTSC 5 A, PAL 3 A
370 (W) X 135 (H) X 420 (D) mm
15 kg
Automatic brightness control method
Automatic exposure
Pump
Pressure switching
Method
Emergency lamp
Filter
Lamp
Average lamp life
Ignition method
Brightness adjustment
Cooling
Color conversion
Emergency lamp
Average emergency lamp life
Type of protection against electric shock
Degree of protection against
electric shock of applied part
Voltage
Frequency
Input current
Dimensions
Weight
San-Ei Building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku, Tokyo, Japan
Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-16, 20097 Hamburg, Germany
2 Corporate Center Drive, Melville, N.Y. 11747-3157, U.S.A.
Keymed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, England
491B River Valley Road #12-01/04,Valley Point Office Tower,Singapore 248373
Rm. 818, South Tower, Beijing Kerry Centre, No.1 Guanghua Road, Chaoyang District, Beijing, 100020, China
117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia
1/104 Ferntree Gully Road, Oakleigh, VIC 3166, Australia
San-Ei Building, 22-2, Nishi Shinjuku 1-chome, Shinjuku-ku, Tokyo, Japan
Postfach 10 49 08, 20034 Hamburg / Wendenstrasse 14-16, 20097 Hamburg, Germany
2 Corporate Center Drive, Melville, N.Y. 11747-3157, U.S.A.
Keymed House, Stock Road, Southend-on-Sea, Essex SS2 5QH, England
491B River Valley Road #12-01/04,Valley Point Office Tower,Singapore 248373
Rm. 818, South Tower, Beijing Kerry Centre, No.1 Guanghua Road, Chaoyang District, Beijing, 100020, China
117071, Moscow, Malaya Kaluzhskaya 19, bld. 1, fl.2, Russia
1/104 Ferntree Gully Road, Oakleigh, VIC 3166, Australia
SIZE : 210×280mm