- Hewlett-Packard Scientific Calculator Owner Manual
CP precision capability 
σ 6
LSLUSL −
CPK  process capability Min(CPU, CPL) 
  where CPU = 
σ 3
xUSL −
 CPL = 
σ 3
LSLx −
Note: In statistics mode, all function keys are available except those 
used for base-n calculations. 
Ex. 9: Enter the following data {2, 5, 5, 5, 5, 9, 9, and 9} and 
calculate Σx, Σx
2
, n, 
x
, S, CP, and CPK, where USL value = 
12 and LSL value = 2. 
In STAT mode  [ 2ndF ] [ STAT ] 
DEG STAT
  0.00 
[ DATA ] 2 
DEG STAT
  2. 
[ DATA ] 5 
DEG STAT
  5. 
[ DATA ] 5 
DEG STAT
  5. 
[ DATA ] 5 
DEG STAT
  5. 
[ DATA ] 5 
DEG STAT
  5. 
[ DATA ] 9 
DEG STAT
  9. 
[ DATA ] 9 
DEG STAT
  9. 
[ DATA ] 9 
DEG STAT
  9. 
Enter all data 
[
ENTER
] 
DEG STAT
  0.00 
x
= ?  [ 
x
 ] 
DEG STAT
  6.13 
n = ?  [ n ] 
DEG STAT
  8.00 
S = ?  [ S ] 
DEG STAT
  2.59 
Σx = ?  [ 2ndF] [ Σx ] 
DEG STAT
 49.00 
Σx 
2
 = ? 
[ 2ndF ] [ Σx
2
] 
DEG STAT
 347.00 
σ= ?  [ 2ndF ] [ σ ] 
DEG STAT
  2.42 σ 
CP 
[ 2ndF ] [ CP ] 12 
DEG STAT
  12. 
USL 
CP 
[
ENTER
] 2 
DEG STAT
  2. 
LSL 
CP 
CP = ? 
[
ENTER
] 
DEG STAT
 0.69 
CPK 
[ 2ndF ] [ CPK ] 
DEG STAT
 12.00 
USL 
CPK 
[
ENTER
] 
DEG STAT
 2.00 
LSL 
CPK 
CPK = ? 
[
ENTER
] 
DEG STAT
 0.57 
Note:  The calculator retains the data you have entered until you exit 
statistics mode. The data is retained even if you turn off the 
calculator or it automatically turns off.   
Viewing Statistics Data 
Press [ DATA ] or [
ENTER
] in edit (ED) mode to view the statistics data 
you have entered. (If you press [ DATA ] the item number of the data 
appears briefly before the value.) 
Ex.10: View the data entered in Ex. 9. 
Method 1 
1.  Press [ 2ndF ] [ EDIT ] to enter edit mode. 
2.  Press [ DATA ] once to view the first data item. 
DEG ED STAT
dAtA 1 
1.5 seconds   
→
DEG ED STAT 
2.00 
3.  Continue pressing [ DATA ] to display each data item. You will 
see data 2, 5.00, data 3, 5.00, data 4, 5.00, data 5, 5.00, data 6, 
9.00, data 7, 9.00, data 8, 9.00 in sequence.   
Method 2 
1. Press [
ENTER
] once to view the first data item. 
DEG ED STAT 
2.00 
2.  Continue pressing [
ENTER
] to display each data item. You will see 
5.00, 5.00, 5.00, 5.00, 9.00, 9.00, 9.00 in sequence. 
Adding a Data Item 
Ex. 11: To add a 9th data item, of value 10, to the Ex. 9 dataset: 
1.  Press [ DATA ] 10 
DEG ED STAT 
10. 
The calculator updates the statistics as you enter data. You can then 
recall the statistics to get : 
x
  = 6.56, n = 9.00, S = 2.74, Σx = 59.00, 
Σx 
2
 = 447.00 and σ= 2.59. 
Editing Statistics Data 
Ex.12: Change the value of data item 1 in Ex. 9 from 2 to 3. 
Method 1 
1.  Press 2 [ 2ndF ] [ DEL ] 3 
Method 2 
1.  Press [ 2ndF ] [ EDIT ] 
DEG ED STAT 
0.00 
2.  Display 2 by pressing [ DATA ] or 
[
ENTER
] 
DEG ED STAT 
2.00 
3.  Enter 3 to overwrite 2. 
DEG ED STAT 
3. 
4. Press [
ENTER
] to make the change. 
5.  Press [ 2ndF ] [ EDIT ] to exit edit mode. 
Ex.13: Based on Ex.9, delete the first data entry (of value 2). 
Method 1 
1.  Press 2 [ 2ndF ] [ DEL ] to delete 2. 
Method 2
1.  Press [ 2ndF ] [ EDIT ] 
DEG ED STAT 
0.00 
2.  Display 2 by pressing [ DATA ] or 
[
ENTER
]. 
DEG ED STAT 
2.00 
3.  Press [ 2ndF ] [ DEL ] 
DEG ED STAT 
5.00 
4.  Press [ 2ndF ] [ EDIT ] to exit edit mode. 
Delete Error 
If you try to delete a value that is not in the dataset, dEL Error 
appears. (Existing data is not affected.) 
Ex.14: Delete 7 from the dataset in Ex.9.
1.  Press 7 [ 2ndF ] [ DEL ] 
DEG STAT   
  dEL Error 
2.  Press any key to clear the message. 
DEG STAT 
0.00 
Ex.15: Delete 5 × 5 from the dataset in Ex.9. 
1.  Press 5 [ × ] 5 [ 2ndF ] [ DEL ] 
DEG STAT   
  dEL Error 
2.  Press any key to clear the message. 
DEG STAT 
0.00 
Weighted Data Entry Method 
Instead of entering each data item individually, you can enter the 
value and the number of occurrences of that value (up to 255). The 
data from Ex.9 can be entered as follows:   
Value  Number of occurrences 
Alternative method 
2 1 
[ DATA ] 2 
5 4 
[ DATA ] 5 [ × ] 4 
9 3 
[ DATA ] 9 [ × ] 3 
where item 1 = 2, items 2 to 5 = 5, and items 6 to 8 = 9. 
Error Conditions 
The indicator FULL appears when any of the following conditions 
occur. Further data entry is not possible. Press any key to clear the 
indicator. Providing that you remain in statistics mode, previously 
entered data entries are unaffected. 
• 
You attempt to enter more than 80 data items. 
• 
The number of occurrences of of any particular data value is 
greater than 255 
• 
The product of the number of data items and the number of 
occurrences is greater than 20400. 
© Copyright 2002 Hewlett-Packard Development Company, L.P. 
Reproduction, adaptation or translation without prior written approval 
is forbidden except as allowed under copyright laws. 
Printed in China.  HDPMR178E23 MWB 
HP part number: F2212-90001 