User guide

Hardware options installation 62
14.
Slide the server into the rack.
15. Power up the server (on page 18).
Using a PCI array controller and the HP Smart Array P400i Controller to support
six hard drives
1. Power down the server (on page 18).
2. Extend the server from the rack (on page 19).
3. Remove the access panel (on page 20).
4. Remove the air baffle. ("Remove the power supply air baffle" on page 21, "Remove the processor
air baffle" on page 22)
5. Remove fan modules 1 and 2 ("Remove and install a fan module" on page 22).
6. Route and connect the data cables:
Connect the PCI SAS or SATA array controller to the SAS hard drive backplane.
Connect the HP Smart Array P400i Controller to the SAS hard drive backplane.
CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables
do not interfere with fan module installation. Be sure to route the cables around the access panel mounting
pin bracket so as not to interfere with access panel installation.
CAUTION: When routing cables, always be sure that the cables are not in a position where they can be
pinched or crimped.
7. Install fan modules 1 and 2 ("Remove and install a fan module" on page 22).
8. Install the air baffle.
9. Install the access panel (on page 20).
10. Slide the server into the rack.
11. Power up the server (on page 18).