CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables
do not interfere with fan module installation. Be sure to route the cables around the access panel mounting
pin bracket so as not to interfere with access panel installation.
13. Connect the hard drive backplane power cable to the system board ("System board components" on
page 11).
14. Install the fan module ("Remove and install a fan module" on page 22).
15. Install the air baffle.
16. Install the access panel (on page 20).
17. Slide the server into the rack.
18. Power up the server (on page 18).
Installing an HP Smart Array P400i Controller cache module and battery pack
1. Power down the server (on page 18).
2. Extend the server from the rack (on page 19).
3. Remove the access panel (on page 20).
4. Remove the air baffle. ("Remove the power supply air baffle" on page 21, "Remove the processor
air baffle" on page 22)
5. Remove fan modules 1 and 2 ("Remove and install a fan module" on page 22).
6. Remove the HP Smart Array P400i Controller ("Removing an integrated HP Smart Array E200i
Controller or an HP Smart Array P400i Controller" on page 50).