Instruction Manual

Using LO100 34
or a MAC address and then click Apply. If both the MAC and an IP address are entered, the IP address is
used.
To set a policy:
1. Select the Policy Enable state and then enter the Policy Number and Destination Selector
information.
o Policy EnableEnables you to selectively enable and disable trap forwarding.
o Policy NumberEnables you to select a policy that will be used in PEF configuration.
o Destination SelectorSpecifies where to send the PET trap from the destinations defined in the
PET Destinations section.
2. Click Apply.
Using the system event log
LO100 captures and stores the IPMI event log for access through a browser, CLP, BIOS Setup Utility, and
RBSU even when the server is not operational. The system event log displays a short description of each
system event. Recorded events include abnormal temperature, fan events, system resets, and system
power loss.
Accessing the system event log from a web browser
The System Event Log screen displays a brief description of the event, including event type, date, time,
source, description, and direction.
To access the System Event Log from a web browser, on the main menu navigation bar, click System
Event Log. To clear the system event log, click Clear Event Log.