The reset command causes a target to cycle from enabled to disabled and then to enabled again.
The set command assigns a specific value to a property or group of properties. The standard syntax
for the set command is set property=new value.
The set command is used to change any changeable property. If the current directory does not
contain the property you want to change, you must specify the target of the property before entering
the property you want to change.
The start command causes the system1 target to power on.
The stop command causes the system1 target to power off.
The version command queries the version of the CLP implementation or other CLP elements. For
example:
/./map1/-> version
Version 1.00
/./map1/-> cd firmware
/./map1/firmware/-> version
Version 1.00
/./map1/firmware/-> show
/./map1/firmware
Targets
Properties
fwversion=0.59
Verbs
cd
version
exit
show
reset
load
help
/./map1/firmware/-> show fwversion
fwversion=0.59
/./map1/firmware/-> fwversion
Invalid command