Specifications

Server component identification 72
System LED and color
Internal health LED
color
Status
DIMM failure (all
slots, amber)
Red No valid or usable memory is installed in the system.
The banks are not populated in the correct order.
System temperature
alert (amber)
Red
System temperature has exceeded OS cautionary level or
critical hardware level.
Fan (amber) Red A required fan has failed.
Amber A redundant fan has failed.
Power supply
backplane failure
(amber)
Red The power supply backplane has failed.
Hot-plug SCSI hard drive LEDs
Item LED description Status
1 Activity status On = Drive activity
Flashing = High activity on the drive or drive
is being configured as part of an array.
Off = No drive activity
2 Online status
On = Drive is part of an array and is
currently working.
Flashing = Drive is actively online.
Off = Drive is offline.
3 Fault status On = Drive failure
Flashing = Fault-process activity
Off = No fault-process activity