Specifications
Removal and replacement procedures 20
2.
Lift up the front bezel and remove it from the chassis.
To replace the component, reverse the removal procedure.
Access panel
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and
the internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
1. Power down the server (on page 16).
2. Extend or remove the server from the rack ("Extending the server from the rack" on page 16).
3. Open the front bezel ("Front bezel" on page 19).
4. Using a Torx T-15 screwdriver, unlock the access panel locking latch.
5. Lift up on the hood latch handle and remove the access panel.
After installing hardware options, replace the access panel. Be sure that the panel is securely locked into
place before powering up the server.
Rack bezel
To remove the component:
1. Remove the access panel ("Access panel" on page 20).
2. Extend or remove the server from the rack ("Extending the server from the rack" on page 16).