Installation guide

4-6 Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide
Compaq Confidential Need to Know Required
Writer: CDresden Project: Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide Comments: Graphics Replaced - Checked
Part Number: 203510-001 File Name: e-ch04 Installing the Rack Server-J.doc Last Saved On: 7/12/01 1:31 PM
Installing Server Rails
To install the server rails on your Compaq ProLiant ML370 Generation 2
server:
IMPORTANT: Install the server rails with the smooth side of the rail against the sever
chassis.
1. Align the four keyholes on one of the server rails above the four spools
on the side of the chassis. The closed, tapered end of the rail points
toward the rear panel of the server.
2. Press the rail against the side of the chassis and slide toward the rear of
the server to snap and lock the rail into place.
Figure 4-4. Attaching a server rail to the chassis
IMPORTANT: Ensure that the first rail is firmly anchored to the chassis before attaching
the second rail.
3. Repeat steps 1 and 2 to secure the second rail to the server.