Use the rack template to identify the required space and location for your
server:
1. Identify the front side of the template.
2. Starting at the bottom of the rack, or at the top of a previously mounted
component, match the hole pattern on the template with the holes on the
vertical rails of the rack. Secure the template against the front of the rack
by pressing the two push tabs through the matching holes.
Figure 4-2. Measuring with the template on the front of the rack
3. Place the template against the vertical rails so that the sides of the
template are aligned with the sides of the rack.
NOTE: Tick marks on the racks vertical rails mark off U-spaces in the rack configuration
and help to maintain the proper alignment.
4. Use a pencil to mark the locations on the outside of the front of the rack
where the spring-load rack rails must be inserted.
5. Place additional pencil marks on the rack at the top edge of the template
to align the template for the next component.
6. Move to the rear of the rack and turn the template over to use the
backside of the template.
7. Repeat steps 2 through 5 with the back of the template on the rear of the
rack.
IMPORTANT: On the rear of the rack, make pencil marks on the inside of the vertical
rails. These markings guide you in installing spring-load rack rails into the interior of the
rack frame.