PCI Expansion Boards
Compaq ProLiant ML370 Generation 2 servers support installation of up to six
PCI expansion boards in the PCI expansion slot area. The slot configuration
consists of two PCI Hot Plug expansion slots and four PCI expansion slots.
PCI Hot Plug slots are designated by black slot release levers.
Use the following figure and table to identify slot locations.
Figure 3-49. PCI expansion slots (tower server)
Table 3-14
PCI Expansion Slots
Item Description Item Description
PCI Hot Plug
expansion slot 1
(64-bit/66-MHz)
PCI expansion slot 4
(64-bit/33-MHz)
PCI Hot Plug
expansion slot 2
(64-bit/66-MHz)
PCI expansion slot 5
(64-bit/33-MHz)
PCI expansion slot 3
(64-bit/33-MHz)
PCI expansion slot 6
(64-bit/33-MHz)
IMPORTANT: Install Remote Insight Lights-Out Edition options in PCI slot 6 only. For
detailed information on installing a Remote Insight Lights-Out Edition board, see