3-48 Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide
Compaq Confidential Need to Know Required
Writer: CDresden Project: Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide Comments: Graphics Replaced - Checked
Part Number: 203510-001 File Name: d-ch03 Installing Hardware Options-J.doc Last Saved On: 7/13/01 11:36 AM
6. Insert the power cord in the redundant power supply.
7. Use the power cord management clip on the power supply to secure the
cord and form a service loop, if needed.
8. Press up on the lower part of the clip to close and lock.
Figure 3-48. Using a management clip to secure the power cord
9. Verify that the power supply LED on the unit is green to indicate that it
is powered up and active.
NOTE: If you remove or replace the primary hot-plug power supply, use the Torx T-15
tool provided with your server to remove the shipping screws from the upper right and left
corners of the power supply unit.
IMPORTANT: For maximum server availability, ensure that the two power supplies are
powered by separate AC power sources.
For additional information about power supply LEDs, see Appendix E, LED
Indicators and Switches.