Installation guide
Installing Hardware Options 3-45
Compaq Confidential – Need to Know Required
Writer: CDresden Project: Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide Comments: Graphics Replaced - Checked
Part Number: 203510-001 File Name: d-ch03 Installing Hardware Options-J.doc Last Saved On: 7/13/01 11:36 AM
Replacing Hot-Plug Fans
When the optional fan cage and all three redundant fans are installed,
individual fans can be hot-swapped at any time as follows:
1. To remove a fan, squeeze the hot-plug fan handles together .
2. Lift the fan out of the fan cage .
Figure 3-44. Removing a hot-plug fan
3. Slide the replacement hot-plug fan into the open fan cage slot and press
down to seat the fan securely.
4. Repeat steps 1 through 3 to replace additional fans as needed.
5. Reinstall the access panel.
6. Power up the server. Ensure that internal health LED on the front panel
and the LED on all installed fans are green. If not, reseat the hot-plug
fan or see Appendix D, “Troubleshooting.”