Table E-3
Hot-Plug SCSI Hard Drive LED Combinations
continued
Activity
LED
Online
LED
Fault
LED
Status
Off Off On OK to replace the drive online.
The drive has failed and has been placed offline.
Off On Off OK to replace the drive online if a predictive
failure alert is received (see the following section
for details), provided that the array is configured
for fault tolerance and all other drives in the array
are online.
The drive is online and configured as part of an
array.
On or
flashing
On Off
OK to replace the drive online if a predictive
failure alert is received (see the following
section for details), provided that the array is
configured for fault tolerance and all other drives
in the array are online.
The drive is online and being accessed.