Installation guide

C-2 Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide
Compaq Confidential – Need to Know Required
Writer: CDresden Project: Compaq ProLiant ML370 Generation 2 Server Setup and Installation Guide Comments: Graphics Replaced
Part Number: 203510-001 File Name: n-appc Server Error Messages-J.doc Last Saved On: 7/12/01 11:18 AM
Table C-1
POST Error Messages
Error Code Audible Beeps Probable Source
of Problem
Action
102-System Board
Failure, DMA test
failed
None 8237 DMA
controllers, 8254
timers, others
Replace the system board. Run the
server setup utility.
102-System Board
Failure, CMOS test
failed
None 8237 DMA
controllers, 8254
timers, others
Replace the system board. Run the
server setup utility.
102-System Board
Failure, Timer test
failed
None 8237 DMA
controllers, 8254
timers, others
Replace the system board. Run the
server setup utility.
207-Invalid Memory
Configuration-
Unsupported DIMM
in Socket X
1 long, 1 short Unregistered DIMMs
or insufficient DIMM
timings
Install registered ECC DIMMs.
207-Invalid Memory
Configuration-
Mismatched DIMMS
within DIMM Group
1 long, 1 short Memory within the
2-DIMM group not
utilized
Install correctly matched DIMMs.
207-Invalid Memory
Configuration-
Mismatched DIMMS
within DIMM Group X
1 long, 1 short Memory within
2-DIMM Group X not
utilized
Install correctly matched DIMMs in
Group X.
209-Online Spare
Memory
Configuration—
Bank C Insufficient
for Bank A.
1 long, 1 short DIMM group
mismatch between
bank A and bank C
Verify the size and speed of the
memory modules installed, then
check your server user
documentation and replace as
indicated.
209-Online Spare
Memory
Configuration—
Bank C Insufficient
for Bank B.
1 long, 1 short DIMM group
mismatch between
bank B and bank C
Verify the size and speed of the
memory modules installed, then
check your server user
documentation and replace as
indicated.
continued