Instruction Manual
Hardware options installation 73
5.
Remove the access panel (on page 25).
6. If installed, remove the PCI air baffle (on page 27).
7. Remove the system air baffle (on page 28).
8. If a Smart Array controller is installed, disconnect the capacitor pack cable from it, and then remove the
capacitor pack holder from the server.
9. Remove any installed full-length PCI expansion cards ("Remove the full-length expansion board" on
page 29).
10. Remove the fan modules and the fan blank (on page 30).
11. Disconnect the power cables from the system board, drive cages, and optical drive.
12. Remove the integrated power supply.
13. Install the redundant power supply assembly:
a. Insert the redundant power supply assembly into the server chassis.