Instruction Manual

Hardware options installation 69
4.
Place the server on its side.
5. Remove the access panel (on page 25).
6. If installed, remove the PCI air baffle (on page 27).
7. Remove the system air baffle (on page 28).
8. Remove any installed full-length PCI expansion cards ("Remove the full-length expansion board" on
page 29).
9. Remove the fan modules and the fan blank (on page 30).
10. Disconnect the drive cage cables:
a. Disconnect the Mini-SAS cable from the system board or from the storage controller option.
b. Disconnect the drive power cable from the drive power connector.
11. Remove the four-bay LFF non-hot-plug drive cage assembly.
12. Install the LFF hot-plug drive cage assembly.
o Box 1