Owner's manual
Hardware options installation 52
10. Enable the feature under the System Options menu in RBSU. For more information on RBSU, refer to
the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website
(http://www.hp.com/servers/smartstart
).
PCI-X expansion cage option
The PCI-X expansion cage option converts one PCI Express slot into two PCI-X slots for additional
expansion board capability. The PCI-X expansion cage does not support expansion boards with internal
cabling requirements.
After installing the PCI-X expansion cage, run RBSU and enable the Optional PCI-X Riser Fan Monitoring
setting from the Advanced Options menu. Enabling this option provides health monitoring of the riser fans
which appear as fans 7 and 8. In addition, both expansion boards installed in the PCI-X expansion cage
appear as slot 6.
IMPORTANT: The following conditions apply for the PCI-X expansion cage:
• Only one HP Smart Array controller can be installed in the PCI-X expansion cage at one
time.
• Only one HP Single-channel U320 storage controller can be installed in the PCI-X
expansion cage at one time.
• An HP Smart Array controller and an HP Single-channel U320 storage controller cannot
both be installed in the PCI-X expansion cage at the same time.
To install the component:
CAUTION: To prevent damage to the server or expansion boards, power down the server and
remove all AC power cords before removing or installing the PCI-X expansion cage.
1. Power down the server (on page 17).
2. Do one of the following:
o Open or remove the tower bezel, as needed ("Open or remove the tower bezel" on page 18).
o Remove the server from the rack (on page 18).
3. Remove the access panel (on page 19).