Manual
Table Of Contents
- HP ProLiant ML100 Series Server User Guide
- Abstract
- Notice
- Contents
- Server operations
- Server setup
- Hardware options installation
- Introduction
- Access panel
- Processor option
- Installing a processor in HP ProLiant ML150 Generation 3 and Generation 5 Servers
- Installing a processor in HP ProLiant ML110 (G2, G3, and G4) and ProLiant ML150 Generation 2 Servers
- Installing a processor in HP ProLiant ML110 Generation 5 Servers
- Installing a processor in HP ProLiant ML115 and ML115 Generation 5 Servers
- SAS or SATA hard drive options
- Hard drive LED cable option
- Removable media device options
- Memory options
- Expansion board options
- Server software and configuration utilities
- Troubleshooting
- Pre-diagnostic steps
- Troubleshooting flowcharts
- Hardware problems
- Power problems
- General hardware problems
- Internal system problems
- System open circuits and short circuits
- External device problems
- Audio problems
- Printer problems
- Mouse and keyboard problems
- Modem problems
- No dial tone exists
- No response occurs when you type AT commands
- AT commands are not visible
- Data is displayed as garbled characters after the connection is established
- Modem does not answer an incoming call
- Modem does not connect to another modem
- Modem disconnects while online
- AT command initialization string is not working
- Connection errors are occurring
- You are unable to connect to an online subscription service
- You are unable to connect at 56 Kbps
- Network controller problems
- Software problems
- Firmware maintenance
- Battery replacement
- Regulatory compliance notices
- Regulatory compliance identification numbers
- Federal Communications Commission notice
- Declaration of conformity for products marked with the FCC logo, United States only
- Modifications
- Cables
- Canadian notice (Avis Canadien)
- European Union regulatory notice
- Disposal of waste equipment by users in private households in the European Union
- Japanese notice
- BSMI notice
- Korean notice
- Laser compliance
- Battery replacement notice
- Taiwan battery recycling notice
- Power cord statement for Japan
- Acoustics statement for Germany (Geräuschemission)
- Electrostatic discharge
- Support and other resources
- Acronyms and abbreviations
- Documentation feedback
- Index
Troubleshooting 77
Latest firmware indicates a defective tape, or head clogs occur regularly
Action: Replace the tape.
Other errors are occurring
Action: Replace the drive.
Diskette drive problems
Diskette drive light stays on
Action:
1. Be sure no loose connections (on page 58) exist.
2. Be sure the diskette is not damaged. Run the diskette utility on the diskette (CHKDSK on some systems).
3. Be sure the diskette is properly inserted. Remove the diskette and reinsert correctly into the drive.
4. Be sure the diskette drive is cabled properly. Refer to the server documentation.
A problem has occurred with a diskette transaction
Action: Be sure the directory structure on the diskette is not bad. Run the diskette utility to check for
fragmentation (CHKDSK on some systems).
Diskette drive cannot read a diskette
Action:
1. If the diskette is not formatted, format the diskette.
2. Check the type of drive you are using and be sure you are using the correct diskette type.
Drive is not found
Action: Be sure no loose connections (on page 58) exist with the drive.
Non-system disk message is displayed
Action:
1. Remove the non-system diskette from the drive.
2. Check for and disconnect any non-bootable USB devices.
Diskette drive cannot write to a diskette
Action:
1. If the diskette is not formatted, format the diskette.
2. Be sure the diskette is not write protected. If it is, use another diskette or remove the write protection.
3. Be sure you are attempting to write to the proper drive by checking the drive letter in the path statement.
4. Be sure enough space is available on the diskette.