User guide
System LEDs and Switches
Table E-8: QuickFind Diagnostic Display LEDs continued
Item Description Status Action
3 Processor
memory board
Off = normal
On = attention required
Processor memory board power failure. If
problem persists, replace
processor/memory board.
4 Processor
power module
Off = normal
On = attention required
PPM power failure. If problem persists,
replace PPM.
If the PPM and the BRD LEDs are both on,
there is a configuration error.
5 Temperature Off = normal
On = attention required
One or more components have
experienced an elevated temperature or a
thermal shutdown.
A thermal shutdown is indicated by the
Therm Trip LED.
• Be sure the processor heatsink is
properly attached.
• Be sure there are no 1.7" DIMMs
installed that prevent airflow across the
processor heatsink).
• Be sure that all fans are installed and
working properly.
• Be sure that the server environment
meets posted requirements.
For information about server environment
requirements refer to the “Optimum
Environment” section in Chapter 3.
6 DIMM Off = normal
On = attention required
DIMM failure or configuration error. Refer to
the IML or POST messages
7 I/O power fault Off = normal
On = attention required
A power fault on the system I/O board
occurred. If problem persists, replace the
system I/O board.
continued
HP ProLiant DL585 Server User Guide E-11