Hardware options installation 63
14.
Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Power up the server (on page 16).
FlexibleLOM option
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some internal
circuitry remain active until AC power is removed.
1. Power down the server (on page 16).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove any attached network cables.
4. Do one of the following:
o Extend the server from the rack (on page 17).
o Remove the server from the rack (on page 16).
5. Remove the access panel (on page 19).
6. Remove the processor air baffle (on page 20).
7. Remove the PCI riser cage (on page 21).
8. Loosen the thumbscrew.
9. Remove the FlexibleLOM blank.
10. Install the component:
a. Firmly seat the FlexibleLOM in the slot.