Hardware options installation 52
If you are installing DIMMs in online spare or lock-step configuration, configure the mode in RBSU ("HP
ROM-Based Setup Utility" on page 79).
Processor and fan module option
When one processor is installed, install fan blanks in slots 1, 2, and 5. When two processors are installed,
install fans in slots 2 and 5; always install a fan blank in slot 1.
The server supports single-processor or dual-processor operation.
CAUTION: To avoid damage to the processor and system board, only authorized personnel
should attempt to replace or install the processor in this server.
CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor
configurations must contain processors with the same part number.
IMPORTANT: If installing a processor with a faster speed, update the system ROM before
installing the processor.
CAUTION: To help prevent the processor pins from bending, do not reset, swap, or exchange
the processor.
To install a processor:
1. Power down the server (on page 16).
2. Do one of the following:
o Extend the server from the rack (on page 17).
o Remove the server from the rack (on page 16).
3. Remove the access panel (on page 19).
4. Remove the processor air baffle (on page 20).
CAUTION: The pins on the processor socket are very fragile. Any damage to them may require
replacing the system board.