Using LO100 44
o On ProLiant ML110 G4 servers, verify or change the following settings:
Configure Console Redirection
Console Redirection—Enabled
EMC Support (SPCR)—Enabled
Flow Control—None
Redirection After BIOS POST—Always
Terminal Type—VT100
Sredir Memory Display Delay—No Delay
I/O Device Configuration—Configure IO Port
Serial Port 1 Address—3F8/IRQ4
o On ProLiant ML115 G1 servers, verify or change the following settings:
Configure Console Redirection
Console Redirection—Enabled
EMS Support (SPCR)—Enabled
Flow Control—None
Redirection After BIOS POST—Always
Terminal Type—VT100
Sredir Memory Display Delay—No Delay
I/O Device Configuration-Configure IO Port
Serial Port 1 Address—3F8/IRQ4
o On ProLiant DL140 G3 and ProLiant DL145 G3 servers, verify or change the following settings:
Console Redirection
Console Redirection—Enabled
EMS Console—Enabled
Baud Rate—115.2K
Console Type—VT100+
Flow Control—None
Continue C.R. after POST—Enabled
I/O Device
Serial Port Mode—BMC
Serial Port A—Enabled
Base I/O address—3F8
Interrupt—IRQ 4
o On ProLiant ML150 G3 servers, verify or change the following settings:
Console Redirection
BIOS Serial console—Enabled
EMC Support (SPCR)—Enabled