minimum configuration information that a valid script must have, see “Sample custom input
script” (page 38).
You can add blank lines and comments to any script to make it easier to read and understand. To
create a comment, enter a semicolon, and then enter the comment text. ACU ignores all text on
the same line after a semicolon.
Sample custom input script
The sample script in this section gives all possible values for each option.
• If an option is shown in bold type, you must enter a value for that option when writing your
own script.
• If a value is shown in bold type, ACU uses that value as a default setting when creating new
logical drives.
You can use this script as a template for your own script. The Control category has the following
options:
• Action mode
• Method mode
Action = Configure|Reconfigure
Method = Custom|Auto ; COMMENT: ACU cannot create a RAID 50 or RAID
60 configuration in Auto mode. You must create such configurations
manually using the Custom setting.
Controller = All | First | Slot [N][:N]| WWN [N]| SerialNumber [N]|
IOCabinet [N],IOBay [N],IOChassis [N],Slot [N],Cabinet [N],Cell [N]
ClearConfigurationWithDataLoss = Yes|No ; COMMENT: This option is now
deprecated.
LicenseKey = XXXXX-XXXXX-XXXXX-XXXXX-XXXXX
DeleteLicenseKey = XXXXX-XXXXX-XXXXX-XXXXX-XXXXX | * ; COMMENT: *
is a wild card that enables you to delete all license keys on the
specified controller.
RAIDArrayID = “XXXXXXXXXXXXXXXXXXXX”
ReadCache = 0|10|20|25|30|40|50|60|70|75|80|90|100
WriteCache = 0|10|20|25|30|40|50|60|70|75|80|90|100
RebuildPriority = Low|Medium|High
ExpandPriority = Low|Medium|High
SurfaceScanDelay = N
SSPState = Enable|Disable
PreferredPathMode = Auto|Manual
; COMMENT: the following five entries are used to optimize the
controller performance for video
MNPDelay = 0|1|2|...|60 ; units are minutes, zero indicates disabled
IRPEnable = Yes|No
DPOEnable = Yes|No
ElevatorSortEnable = Yes|No
QueueDepth = 2|4|8|16|32|Auto
Array = A|B|C|D|E|F|G|...Z|a|b|c|d|e|f
38 Toolkit utilities