c. Edit the DEPLOYSERVER.CMD file for your specific environment.
NOTE: The IFHW and HWQUERY utilities can be used to assist in customizing the
DEPLOYSERVER.CMD script for your environment. For more information about these
utilities, see “Toolkit utilities” (page 23).
The DEPLOYSERVER.CMD file is similar to the following:
rem @echo off
cls
echo [ SCRIPT FOR REMOTE INSTALL OF W2K3 ON TYPICAL SERVER ]
REM pause
echo Retrieving State Information...
%Tools%\System\statemgr /r phase
if errorlevel 3 goto State3
if errorlevel 2 goto State2
if errorlevel 1 goto State1
if errorlevel 0 goto State0
:State0
REM *** Configure the target server hardware by reading the
REM *** configuration information in the script file
echo Running Configuration Replication Utility...
%Tools%\System\conrep -l -f%GlobalData%\HardwareSettings\hwconfig.xml -x%Tools%\System\conrep.xml
echo Setting State Information...
%Tools%\System\statemgr /w Phase 1
:State1
REM===============================================================
REM *** Configure the array controllers by reading the
REM *** configuration information in the script file and stamping
REM *** it onto the array controllers of the target server
REM===============================================================
echo Configuring the Array Controllers...
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 5i Controller"
if errorlevel 1 GOTO NEXT1
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r0.ini
GOTO NEXT5
:NEXT1
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 6i Controller"
if errorlevel 1 GOTO NEXT2
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r1.ini
GOTO NEXT5
:NEXT2
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 5312"
if errorlevel 1 GOTO NEXT3
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r1.ini
GOTO NEXT5
:NEXT3
%Tools%\System\ifhw hpdiscovery.xml %Tools%\System\allboards.xml PCI:"Smart Array 640X Controller"
if errorlevel 1 GOTO NEXT4
%Tools%\ACU\bin\hpacuscripting.exe -i %GlobalData%\ArraySettings\pl-r5.ini
GOTO NEXT5