User Manual

Setup 27
HP BladeSystem c3000 Enclosure
To support network connections for specific signals, install an interconnect module in the bay corresponding
to the embedded adapter or mezzanine signals.
Server blade signal c7000 interconnect bay c3000 interconnect bay Interconnect bay labels
FlexFabric adapter 1
(Embedded)
1 1
FlexFabric adapter 2
(Embedded)
2 1
FlexFabric adapter 3
(Embedded)
1 1
FlexFabric adapter 4
(Embedded)
2 1
Mezzanine 1
3 and 4 2
Mezzanine 2
5 and 6* 3 and 4
7 and 8** 3 and 4
Mezzanine 3
5 and 6** 3 and 4
7 and 8* 3 and 4
* Dual port mezzanine card ports and four-port mezzanine card ports 1 and 2
** Four-port mezzanine card ports 3 and 4
For detailed port mapping information, see the HP BladeSystem enclosure installation poster or the
HP BladeSystem enclosure setup and installation guide on the HP website
(http://www.hp.com/go/bladesystem/documentation).
Connecting to the network
To connect the HP BladeSystem to a network, each enclosure must be configured with network interconnect
devices to manage signals between the server blades and the external network.