User Manual
Table Of Contents
- HP BladeSystem Management Pack for Microsoft® System Center Essentials 2007 User Guide
- Notice
- Contents
- Overview
- Installation
- Installation overview
- Preinstallation checklist
- Installing the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007 (x86 or x64 editons)
- After the installation of the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Uninstalling the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Repairing the installation of the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Using the software
- NT Event lists for HP BladeSystem Enclosure Monitor Service
- Service NT events
- Monitor NT events
- Connecting to Enclosure
- Connected to Enclosure
- Disconnected from Enclosure
- Connection to Enclosure Failed
- Data Collection Started
- Data Collection Completed
- SOAP Event Collection Started
- SOAP Event Collection Stopped
- Data Collection Failed
- SNMP Trap Collection Started
- Health Check Started
- Health Check Stopped
- Health Check restarted a monitoring
- Health Check failed to stop a monitoring
- Monitor Service failed to load the configuration data
- Monitor Service failed to respond
- SOAP NT events
- SNMP trap NT events
- Rack name changed
- Rack enclosure name changed
- Enclosure removed
- Enclosure inserted
- Rack enclosure overheated
- Rack enclosure overheating
- Rack enclosure temperature normal
- Rack enclosure fan failed
- Rack enclosure fan degraded
- Rack enclosure fan OK
- Rack enclosure fan removed
- Rack enclosure fan inserted
- Rack power supply failed
- Rack power supply degraded
- Rack power supply OK
- Rack power supply removed
- Rack power supply inserted
- Rack power subsystem not redundant
- Rack power subsystem input voltage problem
- Rack power subsystem overload
- Server blade removed
- Server blade inserted
- Onboard Administrator degraded
- Onboard Administrator OK
- Onboard Administrator removed
- Onboard Administrator inserted
- Onboard Administrator role primary
- Server Blade E-keying failed
- Server Blade E-keying OK
- Interconnect removed
- Interconnect inserted
- Interconnect failed
- Interconnect degraded
- Interconnect OK
- Server Blade requested to low power
- Server blade removed
- Server Blade inserted
- Technical support
- Acronyms and abbreviations
- Index
NT Event lists for HP BladeSystem Enclosure Monitor Service 51
Rack enclosure fan OK
NT Provider: Blade Enclosure
NT Event ID: 22010
NT Event Type: Informational
NT Event Message:
Rack Enclosure Fan OK.
This trap signifies that an enclosure fan has returned to normal operation.
User Action: None.
Source IP Address: '%1';
Source Name: '%2';
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Fan Location '%8';
Fan Spare Part Number '%9';
Trap Sequence Number '%10'
[SNMP TRAP: 22010 in CPQRACK.MIB]
<a href="https://%1/">Onboard Administrator Web Console</a>
Rack enclosure fan removed
NT Provider: Blade Enclosure
NT Event ID: 22011
NT Event Type: Warning
NT Event Message:
Rack Enclosure Fan Removed.
This trap signifies that the enclosure fan has been removed.
User Action: Replace the fan.
Source IP Address: '%1';
Source Name: '%2';
Rack Name: '%4';
Rack Unique ID: '%5';
Enclosure Name '%6';
Enclosure Serial Number '%7';
Fan Location '%8';