User Manual
Table Of Contents
- HP BladeSystem Management Pack for Microsoft® System Center Essentials 2007 User Guide
- Notice
- Contents
- Overview
- Installation
- Installation overview
- Preinstallation checklist
- Installing the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007 (x86 or x64 editons)
- After the installation of the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Uninstalling the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Repairing the installation of the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Using the software
- NT Event lists for HP BladeSystem Enclosure Monitor Service
- Service NT events
- Monitor NT events
- Connecting to Enclosure
- Connected to Enclosure
- Disconnected from Enclosure
- Connection to Enclosure Failed
- Data Collection Started
- Data Collection Completed
- SOAP Event Collection Started
- SOAP Event Collection Stopped
- Data Collection Failed
- SNMP Trap Collection Started
- Health Check Started
- Health Check Stopped
- Health Check restarted a monitoring
- Health Check failed to stop a monitoring
- Monitor Service failed to load the configuration data
- Monitor Service failed to respond
- SOAP NT events
- SNMP trap NT events
- Rack name changed
- Rack enclosure name changed
- Enclosure removed
- Enclosure inserted
- Rack enclosure overheated
- Rack enclosure overheating
- Rack enclosure temperature normal
- Rack enclosure fan failed
- Rack enclosure fan degraded
- Rack enclosure fan OK
- Rack enclosure fan removed
- Rack enclosure fan inserted
- Rack power supply failed
- Rack power supply degraded
- Rack power supply OK
- Rack power supply removed
- Rack power supply inserted
- Rack power subsystem not redundant
- Rack power subsystem input voltage problem
- Rack power subsystem overload
- Server blade removed
- Server blade inserted
- Onboard Administrator degraded
- Onboard Administrator OK
- Onboard Administrator removed
- Onboard Administrator inserted
- Onboard Administrator role primary
- Server Blade E-keying failed
- Server Blade E-keying OK
- Interconnect removed
- Interconnect inserted
- Interconnect failed
- Interconnect degraded
- Interconnect OK
- Server Blade requested to low power
- Server blade removed
- Server Blade inserted
- Technical support
- Acronyms and abbreviations
- Index

Using the software 19
Class Property name Sample value
— Bay Number 3
— Type Ethernet
— Product Name Brocade 4/12 SAN Switch for HP c-Class
BladeSystem
— Management IP Address 10.77.77.77
— User Assigned Name Swd77
— Part Number AE370A
— Spare Part Number 411120-001
— Serial Number CN8632600D
— Manufacturer BORCADE
— Temperature Sensor Present
HP BladeSystem Onboard
Administrator Collection
Name Onboard Administrators – IT03-ENC-A
— Number of Present OA Bays 2
— Enclosure Serial Number USE6321FJC
— Server Name N/A
HP BladeSystem Onboard
Administrator
Name <Active|Standby> Onboard Administrator
— Bay Number 1
— Spare Part Number 414055-001
— Firmware Version 2.02
— Manufacturer HP
— Part Number 407296-001
— Role ACTIVE
— IP Address 192.168.21.68
— Serial Number O96MK0260
— Device Name BladeSystem c7000 Onboard Administrator
HP BladeSystem Power
Subsystem
Name Power Subsystem—IT03-ENC-A
— Enclosure Power Mode AC Redundant with Power Ceiling
— Enclosure Serial Number USE6321FJC
— Server Name N/A
HP BladeSystem Power
Supply
Name Power Supply – Bay 1
— Bay Number 1
— Present Output (Watts) 405
— Output Capacity (Watts) 2250
— Spare Part Number 411099-001
— Serial Number 5A22B0AHLTA0AB
— Part Number 412138-B21