User Manual
Table Of Contents
- HP BladeSystem Management Pack for Microsoft® System Center Essentials 2007 User Guide
- Notice
- Contents
- Overview
- Installation
- Installation overview
- Preinstallation checklist
- Installing the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007 (x86 or x64 editons)
- After the installation of the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Uninstalling the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Repairing the installation of the HP BladeSystem Management Pack 1.0 for System Center Essentials 2007
- Using the software
- NT Event lists for HP BladeSystem Enclosure Monitor Service
- Service NT events
- Monitor NT events
- Connecting to Enclosure
- Connected to Enclosure
- Disconnected from Enclosure
- Connection to Enclosure Failed
- Data Collection Started
- Data Collection Completed
- SOAP Event Collection Started
- SOAP Event Collection Stopped
- Data Collection Failed
- SNMP Trap Collection Started
- Health Check Started
- Health Check Stopped
- Health Check restarted a monitoring
- Health Check failed to stop a monitoring
- Monitor Service failed to load the configuration data
- Monitor Service failed to respond
- SOAP NT events
- SNMP trap NT events
- Rack name changed
- Rack enclosure name changed
- Enclosure removed
- Enclosure inserted
- Rack enclosure overheated
- Rack enclosure overheating
- Rack enclosure temperature normal
- Rack enclosure fan failed
- Rack enclosure fan degraded
- Rack enclosure fan OK
- Rack enclosure fan removed
- Rack enclosure fan inserted
- Rack power supply failed
- Rack power supply degraded
- Rack power supply OK
- Rack power supply removed
- Rack power supply inserted
- Rack power subsystem not redundant
- Rack power subsystem input voltage problem
- Rack power subsystem overload
- Server blade removed
- Server blade inserted
- Onboard Administrator degraded
- Onboard Administrator OK
- Onboard Administrator removed
- Onboard Administrator inserted
- Onboard Administrator role primary
- Server Blade E-keying failed
- Server Blade E-keying OK
- Interconnect removed
- Interconnect inserted
- Interconnect failed
- Interconnect degraded
- Interconnect OK
- Server Blade requested to low power
- Server blade removed
- Server Blade inserted
- Technical support
- Acronyms and abbreviations
- Index
Installation 10
is required to monitor the state of the HP BladeSystem c-Class enclosures and to capture SNMP Trap
packets generated by HP BladeSystem c-Class enclosures.
• An account is set up with the HP Onboard Administrator Web console to monitor the enclosure.
During the last step of the installation, the user is asked to launch the Enclosure Monitor Manager to
register HP BladeSystem c-Class enclosures with user name and password
• An account is set up on the HP Onboard Administrator Web console to monitor the enclosure.
During the last step of the installation, the user is asked to enter a user name and password in the
Enclosure Monitor Manager.
• The SNMP Trap setting to the HP Onboard Administrator Web is enabled, and the community string
and IP Address of the System Center Essentials 2007 server is registered.
• The Windows® SNMP service is configured and active on the System Center Essentials 2007 server.
• PowerShell 1.0 is installed on the System Center Essentials 2007 server. PowerShell 1.0 64 bit
release must be installed for x64 platforms.
Installing the HP BladeSystem Management Pack
1.0 for System Center Essentials 2007 (x86 or x64
editions)
1. Close the System Center Essentials console if it is running.
2. Install either the HPBladeSystemMPforSCE1_0_x64.msi file or the
HPBladeSystemMPforSCE1_0_x86.msi file on a system hosting the System Center Essentials
Management Server.
3. Execute either theHPBladeSystemMPforSCE1_0_x64.msi file or the
HPBladeSystemMPforSCE1_0_x86.msi file to begin the installation process.