Instruction Manual
Hardware options installation 25
6.
Install the DIMM.
7. Install the DIMM baffle.
8. Connect the hard drive cables ("Hot-plug SAS/SATA hard drive cabling" on page 39).
9. Connect the cache module capacitor cable ("Cache module capacitor cabling" on page 39).
10. Install the access panel (on page 15).
11. Install the server blade ("Installing a server blade" on page 18).
Hot-plug SAS or SATA hard drive option
IMPORTANT: To avoid improper operation, install only hot-plug hard drives in this server
blade.
IMPORTANT: The following configurations are not supported:
• Installation of both SAS and SATA hard drives in a single RAID volume
• Installation of SSD and rotating media hard drives in a single RAID volume
A Smart Array P410i controller with an embedded FBWC module supports either two hot-plug SAS or two
hot-plug SATA hard drives. Hard drive activity is indicated by the hard drive LEDs on the hard drives.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.