Reference Guide

MIB descriptions
COLUBRIS-802DOT11-MIB
3-119
coDot11PHYType
.1.3.6.1.4.1.8744.5.4.3.1.1.1 read-only
This is an 8-bit integer value that identifies the PHY type supported by the attached PLCP
and PMD. Currently defined values and their corresponding PHY types are: FHSS 2.4 GHz
= 01 , DSSS 2.4 GHz = 02, IR Baseband = 03, OFDM 5 GHz = 04.
coDot11CurrentRegDomain
.1.3.6.1.4.1.8744.5.4.3.1.1.2 read-only
The current regulatory domain this instance of the PMD is supporting. This object
corresponds to one of the RegDomains listed in coDot11RegDomainsSupported.
coDot11TempType
.1.3.6.1.4.1.8744.5.4.3.1.1.3 read-only
There are different operating temperature requirements dependent on the anticipated
environmental conditions. This attribute describes the current PHY’s operating
temperature range capability. Currently defined values and their corresponding
temperature ranges are:
Type 1 = X’01’-Commercial range of 0 to 40 degrees C,
Type 2 = X’02’-Industrial range of -30 to 70 degrees C.
coDot11CurrentOperFrequency
.1.3.6.1.4.1.8744.5.4.3.1.1.4 read-only
The current operating frequency channel of the radio.
coDot11CurrentOperPHYType
.1.3.6.1.4.1.8744.5.4.3.1.1.5 read-only
The current operating PHY type of the radio.
coDot11Sensitivity
.1.3.6.1.4.1.8744.5.4.3.1.1.6 read-write
Receiver sensitivity of the radio.
coDot11RadioEnabled
.1.3.6.1.4.1.8744.5.4.3.1.1.7 read-write
When True the radio is enabled.
coDot11OperatingMode
.1.3.6.1.4.1.8744.5.4.3.1.1.8 read-write
Operating mode of the radio. Available options are:
Access point and Wireless links: Standard operating mode provides support for all
wireless functions.
Access point only: Only provides access point functionality, local mesh links cannot be
created.
Wireless links only: Only provides local mesh functionality. Wireless client stations
cannot connect.
Monitor: Disables access point and local mesh functions. Use this option for continuous
scanning across all channels in all supported wireless modes.
Sensor: Enables RF sensor functionality on this radio. Operation of this feature requires
that the appropriate license is installed.