Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

Fabric OS Message Reference 657
53-1002149-01
SSMD-1214
101
SSMD-1214
Message <timestamp>, [SSMD-1214], <sequence-number>,, WARNING, <system-name>, QoS failed
programming interface 0x<Interface ID> CoS Tail Drop Threshold.
Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface CoS Tail Drop Threshold feature.
Recommended
Action
Delete and reapply the QoS CoS Tail Drop Threshold policy. Restart or power cycle the switch.
Severity WARNING
SSMD-1215
Message <timestamp>, [SSMD-1215], <sequence-number>,, WARNING, <system-name>, QoS failed
programming interface 0x<Interface ID> CoS Tail Drop Threshold.
Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface CoS Tail Drop Threshold feature.
Recommended
Action
Delete and reapply the QoS CoS Tail Drop Threshold policy. Restart or power cycle the switch.
Severity WARNING
SSMD-1216
Message <timestamp>, [SSMD-1216], <sequence-number>,, WARNING, <system-name>,QoS failed
programming interface 0x<Interface ID> Pause.
Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected error in
programming the dataplane ASIC for enforcing the interface Pause feature.
Recommended
Action
Delete and reapply the QoS Pause policy. Restart or power cycle the switch.
Severity WARNING
SSMD-1217
Message <timestamp>, [SSMD-1217], <sequence-number>,, WARNING, <system-name>, QoS CEE
could not comply with FCoE scheduler policy for CEE Map <CEE Map name>.
Probable Cause Indicates the DCE System Services Manager (SSM) was unable to translate CEE Map and FCoE
configuration into an ETS scheduler policy implementable by the dataplane ASIC.
Recommended
Action
Redefine CEE Map and FCoE into a configuration that translates into into an ETS scheduler policy
requiring 8 or fewer Traffic Class.