Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

652 Fabric OS Message Reference
53-1002149-01
SSMD-1005
101
Probable Cause Indicates that the specified function has failed to unlock the mutex (semaphore).
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
SSMD-1005
Message <timestamp>, [SSMD-1005], <sequence-number>,, ERROR, <system-name>, SSM startup
failed.
Probable Cause Indicates the DCE System Services Manager (SSM) encountered an unexpected, severe error
during basic startup and initialization.
Recommended
Action
Restart or power cycle the switch .If the condition persists then download a new firmware version
using the firmwareDownload command. Refer to the Fabric OS Command Reference Manual for
more information on this command.
Severity ERROR
SSMD-1006
Message <timestamp>, [SSMD-1006], <sequence-number>,, ERROR, <system-name>, Error while
configuring ACL <ACL name> on interface <Interface name>.
Probable Cause Indicates that an error was encountered during TCAM entry programming.
Recommended
Action
Try again after sometime. If the problem persists, run the supportSave command and then reboot
or power cycle the switch.
Severity ERROR
SSMD-1007
Message <timestamp>, [SSMD-1007], <sequence-number>,, ERROR, <system-name>, Error while
removing ACL <ACL name> from interface <Interface name>.
Probable Cause Indicates that an error was encountered during TCAM entry programming.
Recommended
Action
Try again after sometime. If the problem persists, run the supportSave command and then reboot
or power cycle the switch.
Severity ERROR