Fabric OS Message Reference v7.0.0 (53-1002149-01, April 2011)

398 Fabric OS Message Reference
53-1002149-01
HAM-1005
46
Fastboot
Giveup Master:SYSM
CP Faulty:SYSM
FirmwareDownload
ConfigDownload:MS
ChangeWWN:EM
Reboot:WebTool
Fastboot:WebTool
Software Fault:Software Watchdog
Software Fault:Kernel Panic
Software Fault:ASSERT
Reboot:SNMP
Fastboot:SNMP
Reboot
Chassis Config
Reboot:API
Reboot:HAM
EMFault:EM
Recommended
Action
Check the error log on both CPs for additional messages that might indicate the reason for the
reboot.
Severity INFO
HAM-1005
Message <timestamp>, [HAM-1005], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,
<system-name>, HeartBeat Miss reached threshold.
Probable Cause Indicates that either the active control processor (CP) EMAC controller or the standby CP is down.
The active CP will run a diagnostic test on the EMAC controller and will wait for the standby CP to
reset it if it is down.
Recommended
Action
No action is required.
Severity INFO
HAM-1006
Message <timestamp>, [HAM-1006], <sequence-number>, SLOT cp-slpt-number | FFDC | CHASSIS,
FFDC, CRITICAL, <system-name>, EMAC controller for Active CP is BAD.
Probable Cause Indicates that the local EMAC controller on the active control processor (CP) is BAD as determined
by the diagnostic test run by the HAM module.